MAC
MAC

 
BIO-SAFETY CABINETS
 
  MSW-164 BIOLOGICAL SAFETY CABINET “MAC”
   
 
  • Working table is made of heavy gauge stainless steel sheet.
  • Fitted with U.V. Germicidal Light and Static Pressure Manometer.
  • Side panels and front doors are made out of thick transparent plexi glass duly framed.
  • Unit is fitted with Pre-Filter and HEPA Filter.
  • Air is drawn through Pre-Filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency retaining all air-borne particles of size 0.3 micron and larger.
  • With statically and dynamically balanced motor assembly.
  • Heavy Duty Motor operates with minimum noise level.
  • The working area is illuminated by fluorescent lighting fitted to the unit.
  • The unit is also convertible to the conventional Vertical Laminar Flow bench with downward air flow by lifting the sliding front door upwards.
  • Air is sucked through the pre-filter and the excess air is thrown out from the top through a HEPA filter.
  • Supplied with glove ports and gauntlets, HEPA filter, pre-filter, U.V. light and fluorescent light.
  • To work on 220/230 volts A.C. supply

  • (A) AS PER CLASS II (PARTIAL EXHAUST AND PARTIAL RECIRCULATORY MODE)
    In addition to the above features of a standard Vertical Laminar Flow Bench, the CLASS II Bio-safe cabinets have arrangements for re-circulating a part of the air thus creating highest level of clean air. This cabinet is vented, with partial air exhausted from the cabinet and partial is recirculated back.
    Model
    Working Size
    Size of HEPA Filter
    No. of HEPA Filter
    Illumination
    (a) Whole Cabinet made of wooden board Laminated with Sunmica
    (b) Whole Cabinet made of cold rolled steel Duly powder coated
    (c) Whole Cabinet made out of Stainless Steel
    OPTIONAL ACCESSORIES (For class II units only)
    (a) Special exhaust system suitable for 6' duct
    (b) Exhaust ducting-per running ft.
    (c) Virus burn out unit
    (d) Gas burner
    (e) Front door made of transparent POLYCARBONATE SHEET in lieu of plexi-glass to cost extra
    (f) Magnehelic Pressure Differential Gauge for pressure across HEPA filter
    (g) Magnehelic Pressure Differential Gauge for pressure across Work Space.
    (h) Electronic Filter Choke Alarm
    (B) AS PER CLASS III (100% EXHAUST MODE FOR WORK ON HIGH RISK AGENTS)
  • Besides standard specifications of a class II Bio-Safe Cabinets these units are available with following features:
  • This Class III cabinet is totally enclosed ventilated cabinet type. Operations within the Class III cabinet are conducted through attached glove ports. When in use, the Class III cabinet maintains negative air pressure throughout. Supply air is drawn into the cabinet through HEPA filters.
  • The cabinet exhaust air is filtered by HEPA filter, before discharge. The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facility’s ventilation system.
  • Exhaust system of these units ensure 100% exhaust of air from the work area via suitable plenum under the S.S. perforated table.
  • These units works in tandem with the main air flow system.
  • These units are provided with built in HEPA filter, virus burn out system and an additional U.V.
  • germicidal light and a HEPA filter at exhaust ensuring total environment protection.
    Model
    (a) Whole Cabinet made of wooden board Laminated with Sunmica.
    (b) Whole Cabinet made of cold rolled steel Duly powder coated.
    (c) Whole Cabinet made out of Stainless Steel.
    OPTIONAL ACCESSORIES

    (a) Front door made of transparent POLYCARBONATE SHEET in lieu of plexi-glass to cost extra
    (b) Magnehelic Pressure Differential Gauge for pressure across HEPA filter
    (c) Magnehelic Pressure Differential Gauge for pressure across Work Space.
    (d) Electronic Filter Choke Alarm
  OPTIONAL ACCESSORIES (For class II units only)  
  1. Special exhaust system suitable for 6' duct.
  2. Exhaust ducting-per running ft.
  3. Virus burn out unit.
  4. Gas burner.
  5. Electronic Differential Pressure Monitor. (Electronic Filter Choke Alarm)  
 
 
  MSW-165 AIR SHOWER “MAC”
(CE, ISO & GMP CERTIFIED)
   
 
  • Modular construction for easy transportation and installation at site.
  • Grafted floor around 6 inches above datum level.
  • Illumination level equivalent to 100 foot candles.
  • Under operation/entry both doors get locked automatically.
  • In event of any emergency/power failure the doors get unlocked automatically.
  • Both the aluminium framed doors with see thru acrylic/glass are fitted with auto lock arrangement.
  • Unit is fitted with Pre-filter and HEPA Filter.
  • Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and larger.
  • Using a dynamic machine, the blower and motor assembly is statically & dynamically balanced.
  • Heavy Duty Motor operates with minimum noise level.
  • Automatic adjustable time control device is fitted with solid state controls for automatic and smooth operation.
  • Specially designed to provide jets of high velocity clean air for use at entrance from change room to clean room.
  • Size of the air shower chamber is 3'(W) x 3' (D) x 6' (H).

  • MATERIAL OF CONSTRUCTION
    (a)        Whole cabinet made of wooden board laminated with sunmica
    (b)        Whole cabinet made of cold rolled steel sheet duty powder coated
    (c)        Whole cabinet made of Stainless Steel sheet.
 
 

MSW-167 FUME HOOD “MAC”

 
 
  • Fabricated out of thick wooden board.
  • These are designed so as to throw-out all toxic/harmful vapors, thus protecting costly instruments and the person working in the lab.
  • Outer is finished with sunmica and inner epoxy painted.
  • Working table top is made of stainless steel and a small wash basin with connections provided for inlet and outlet of water.
  • The front door moves vertically up and down with concealed counter balanced weight.
  • The unit is fitted with fluorescent light and a gas cock for gas/air supply.
  • The front facing panel is fitted with 15/5 Amp socket with switches for exhaust system and fluorescent light.
  • To work on 220 / 230 volts A.C. Supply.
  • Working Size:
    Price
    OPTIONAL ACCESSORIES
    (a) FC mounting base with storage space and door.
    (b) S.S. Lining on work area walls
    (c) Lead lining on work walls for use as Radio-Isotope Fume Hood
    (d) Fume duct per running feet.
 
  MSW-170 TISSUE CULTURE HOOD/INNOCULATION CHAMBER “MAC”  
 
  • "MAC" Tissue Culture Hoods are most suitable for circulation free environment to eliminate cross contamination in sterile techniques involving culture growth, tissue staining and virus harvestings.
  • The convenient working height of table top and ample working space provides working ease for uses while media preparation.
  • Working table top made out of thick stainless steel sheet(SS-304 grade).
  • The front door is made of thick transparent plexiglass and has arrangement for keeping the door open if desired.
  • All "MAC" units are fitted with one U.V. germicidal light and one fluorescent light for daylight vision.
  • (A) Outside dimenision : 900mm X 600mm (ht at back)
    (B) -do- same as above but with front door provided with GLOVE PORT AND        GAUNTLETS and exhaust system for 6 feet duct, for converting the unit into        a innoculation chamber.
 
  MSW-172 FUMIGATION CHAMBER "MAC"  
 
  • I deal for sterilization and deacidification of documents and books and ideal materials carrying out documentary heritage.
  • Double walled unit has outer made of cold rolled steel sheet duly powder coated.
  • Inner chamber and perforated shelves are made up of stainless steel.
  • Meant for fumigating specimens with insecticide for preservation.
  • Specimens may be placed in the chamber, insecticide sprayed and the lockable airtight door be closed.
  • Air circulating fan is provided on one side which helps in rotating the insecticide fumes throughout the chamber properly.
  • The perforated sheet is used when small specimens are to be fumigated. First small specimens may be placed in chamber, then the perforated sheet placed in the chamber and the specimens kept on it followed by the process of spraying the insecticide and switching on the fan.
  • Available with and without temperature control arrangement.
  • Temperature controlled models are fitted with MICROPROCESSOR BASED DIGITAL TEMPERATURE CUM INDICATOR.
  • To work on 220/230V AC. Supply.
    SIZE
    (a)
    605mm(W) x 605mm(D) x 910mm(H)
 
Send Enquiry     TOP
 
MAC
 




Copyright © MAC. All Right Reserved.
MAC